Shop is under construction. It will be ready soon...
Coaxial cable CB135, 100m 70070
Coaxial cable CB135, 100m 70070
Coaxial cable CB135, 100m
Universal coaxial cable type RG6 with a central conductor made of CCS and double shielding from aluminum wire Al, white color. The cable is designed for all applications of transmission, TV, and SAT signals in a less demanding environment. Thanks to the material used for the central conductor and braiding, the cable is exceptionally resistant to weather conditions, humidity, and corrosion.
Technical data:
max. resistance at 20
°C, (Ohm/km) - outer core: 45.2
shielding coverage: 28 %
warranty period: 2 years
FPE = foam dielectric: yes
PE = polyethylene dielectric: no
APE = air dielectric: no
suitable for outdoor use: no
inner conductor diameter: 1.02 mm
recommended types of connectors - F pressed: *K7220
min. bending radius single/multiple: 30/60 mm
UV resistant: no
sales packaging: 100 m, coil
max. attenuation at 20 °C (dB/100m) 1,000 MHz: 21.9
min. reflection attenuation at 20 °C (dB) 10–300 MHz: 25
min. shielding attenuation (dB) 10 ~ 800 MHz: >110
insulation resistance between cores at 20 °C (MOhm/km): 500
PES = foil layer: no
max. attenuation at 20 °C (dB/100m) 2,000 MHz: 33.5
recommended types of connectors - F screw: *K7331
dielectric type, diameter: FPE 4.8 mm
max. attenuation at 20 °C (dB/100m) 860 MHz: 20.7
max. resistance at 20 °C (Ohm/km) - inner core: 25.3
weight (kg/km): 41
min. reflection attenuation at 20 °C (dB) 300–600 MHz: 23
max. attenuation at 20 °C (dB/100m) 650 MHz: 18.3
type of coaxial cable: CB135
min. reflection attenuation at 20 °C (dB) 600–900 MHz: 20
installation temperature: +5 °C to +60 °C
number of shields: 3
packing method - marked by metering: 1–100 m
shielding I. foil: 1× Al/PES
cable sheath material: PVC
inner conductor material: galvanized steel wire (CCS)
cable sheath diameter: 6.8 mm
impedance: 75 Ohm
packing method - type of coil: paper coil with printing
max. attenuation at 20 °C (dB/100m) 10 MHz: 2.28
shielding material: aluminum (Al)
max. attenuation at 20 °C (dB/100m) 450 MHz: 15
capacity (pF/m): 75
shortening factor: 0.85
shielding diameter: 64× 0.10 mm?
packing method - length: 100 m
shielding II. foil: Al/Pes
storage temperature: -20 °C to +75 °C
max. attenuation at 20 °C (dB/100m) 100 MHz: 7.2
fire reaction class: Eca
intended use: internal distributions, resistant to interference, CLASS A
hazardous substances: none
number of shielding wires: 64× 0.12 mm
cable sheath color: white
construction of power conductors: not specified
insulation of power conductors: not specified
cross-section of power conductors: not specified
color of insulation of power conductors: not specified