Shop is under construction. It will be ready soon...
Coaxial cable CB113UV, 100m 70303
Coaxial cable CB113UV, 100m 70303
Coaxial cable CB113UV, 100m
High-quality coaxial cable with a core conductor made of pure copper BC and triple shielding TRISHIELD made of tinned copper CuSn. The cable is designed for all demanding CCTV, TV, and SAT signal transmission applications.
Thanks to the material used for the core conductor and braiding, the cable is exceptionally resistant to weather conditions, moisture, and corrosion. The cable is UV radiation resistant for outdoor installations.
Technical data:
shielding coverage: >84 %
max.surface resistance at 20 °C, (Ohm/km) - outer core: 45.9
warranty period: 5 years
APE = air dielectric: no
sales packaging: 100 m, reel
recommended types of connectors - F compressed: *K7220
UV resistant: yes
FPE = foam dielectric: yes
PE = polyethylene dielectric: no
inner conductor diameter: 1.13 mm
suitable for outdoor use: yes
recommended types of connectors - F screw: *K7351
min. bending radius single/multiple: 30/60 mm
min. reflection attenuation at 20 °C (dB) 10–300 MHz: 31
insulation resistance between cores at 20 °C (MOhm/km): 500
type of coaxial cable: CB113UV
max. attenuation at 20 °C (dB/100m) 2,000 MHz: 28.2
weight (kg/km): 43.5
max.surface resistance at 20 °C (Ohm/km) - inner core: 25.7
min. reflection attenuation at 20 °C (dB) 300–600 MHz: 25
min. reflection attenuation at 20 °C (dB) 600–900 MHz: 23
min. shielding attenuation (dB) 10 ~ 800 MHz: >97
max. attenuation at 20 °C (dB/100m) 650 MHz: 15.1
PES = foil layer: no
max. attenuation at 20 °C (dB/100m) 860 MHz: 17.87
dielectric type, diameter: FPE 4.8 mm
max. attenuation at 20 °C (dB/100m) 1,000 MHz: 19.5
number of shieldings: 3
packaging method - length: 100 m
shielding material: tinned copper (CuSn)
packaging method - length marking: 1–100 m
packaging method - type of reel: paper reel
installation temperature: +5 °C to +60 °C
outer sheath diameter: 7.1 mm
max. attenuation at 20 °C (dB/100m) 100 MHz: 5.8
capacity (pF/m): 52
max. attenuation at 20 °C (dB/100m) 10 MHz: 2.28
material of inner conductor: copper (Cu)
impedance: 75 Ohm
material of cable sheath: UV resistant PVC
shielding II. foil: not present
shielding I. foil: 1× Al/PES
diameter of shielding: 144× 0.12 mm2
velocity factor: 0.84
max. attenuation at 20 °C (dB/100m) 450 MHz: 12.8
storage temperature: -20 °C to +75 °C
intended use: outdoor wiring, tertiary distributions
hazardous substances: none
reaction to fire class: Eca
number of shielding wires: 144× 0.12 mm
color of cable sheath: black
color of insulation of power conductors: not specified
cross-section of power conductors: not specified
insulation of power conductors: not specified
construction of power conductors: not specified